TSS EX1 sc Triclamp Suspended solids probe, stainless steel, ball valve fitting, ATEX

TSS EX1 sc Triclamp Suspended solids probe, stainless steel, ball valve fitting, ATEX
Produktnr.: LXV328.99.20001
Stykpris Kontakt os
Afsendes indenfor 2 uger

TSS sc probes have been specially developed for industrial applications

Turbidity from 0.001 - 4,000 FNU and suspended solids from 0.001 - 500 g/L

8 measurement signals cover the total range and deliver measured values in conformity with the relevant standards

Excellent stability thanks to comprehensive compensation for interference factors

TSS sc has a unique compensation system to overcome the effects of air bubbles

Hvad er der i boksen

Turbidity & Suspended Solids sensor, user manual

Specifikationer

Applikation: Hazardous locations
automatisk visker: Nej
Diameter: 48.5 mm
Flow: Max. 3 m/s (the presence of air bubbles affects the measurement)
Garanti: 24 måneder
Hvad er der i boksen: Turbidity & Suspended Solids sensor, user manual
installationsstil: Weld On TriClamp Fitting
Kabellængde: 10 m
Kalibrering: Turbidity (TRB): Factory calibrated
Solids (TS): To be calibrated by customer on site
Zero point: Permanently calibrated in the factory
Kalibreringsmetode: Turbidity: Formazin or Stablcal Standard (at 800 NTU). Requires a calibration kit.
Suspended Solids: Sample specific, based on gravimetric analysis with a correction factor procedure.
Kompatibel med: SC200, SC1000, SC4500. All controllers sold separately
Længde: 448 mm
Målemetode: Combined multiple beam alternating light method with infrared diode system and beam focusing
Turbidity (TRB): 2-channel 90º scattered light measurement in accordance with DIN EN ISO 7027, wavelength = 860 nm
Solids (TS): 90º and 120º scattered light measurement, wavelength = 860 nm
Måleområde: Turbidity (TRB): 0.001 - 9999 NTU
Solids (TSS): 0.001 - 500 g/L
Materiale: Optics Carrier and Sleeve: stainless steel 1.4460 / stainless steel 1.4404; Wiper Arm: stainless steel 1.4581; Wiper Rubber: silicone rubber (standard) Optional: FKM/FPM (LZX578); Wiper Shaft: stainless steel 1.4104
Max Temperatur: 50 °C
Measuring range TSS: 0,001 - 500 g/L
Measuring range turbidity: 0,001 - 4000 FNU
Model: TSS EX1 sc
Monteringskonfigurationer: TriClamp
Nøjagtighed: Turbidity up to 1000 FNU/NTU: < 5 % of measurement value or ±0.01 NTU, whichever is greater
Omgivelsestemperatur: 0 - 50 °C
  -10 - 50 °C
Parameter: Turbidity, Suspended Solids
Repeterbarhed: TSS content: < 4 %
Turbidity: < 3 %
Responstid T90: 1 - 300 s adjustable
Specielle fordele: with Triclamp
Trykområde: 10 bar or 100 m
Vedligeholdelse interval: 1 h/måned
Vægt: ca,