Applikation:
Hazardous locations
automatisk visker:
Nej
Diameter:
48.5 mm
Flow:
Max. 3 m/s (the presence of air bubbles affects the measurement)
Garanti:
24 måneder
Hvad er der i boksen:
Turbidity & Suspended Solids sensor, user manual
installationsstil:
Ball Valve Insertion
Kabellængde:
10 m
Kalibrering:
Turbidity (TRB): Factory calibrated
Solids (TS): To be calibrated by customer on site
Zero point: Permanently calibrated in the factory
Kalibreringsmetode:
Turbidity: Formazin or Stablcal Standard (at 800 NTU). Requires a calibration kit.
Suspended Solids: Sample specific, based on gravimetric analysis with a correction factor procedure.
Kompatibel med:
SC200, SC1000, SC4500. All controllers sold separately
Længde:
488 mm
Målemetode:
Combined multiple beam alternating light method with infrared diode system and beam focusing
Turbidity (TRB): 2-channel 90º scattered light measurement in accordance with DIN EN ISO 7027, wavelength = 860 nm
Solids (TS): 90º and 120º scattered light measurement, wavelength = 860 nm
Måleområde:
Turbidity (TRB): 0.001 - 9999 NTU
Solids (TSS): 0.001 - 500 g/L
Materiale:
Optics Carrier and Sleeve: stainless steel 1.4460 / stainless steel 1.4404; Wiper Arm: stainless steel 1.4581; Wiper Rubber: silicone rubber (standard) Optional: FKM/FPM (LZX578); Wiper Shaft: stainless steel 1.4104
Max Temperatur:
50 °C
Measuring range TSS:
0,001 - 500 g/L
Measuring range turbidity:
0,001 - 4000 FNU
Model:
TSS EX1 sc
Monteringskonfigurationer:
Insertion
Nøjagtighed:
Turbidity up to 1000 FNU/NTU: < 5 % of measurement value or ±0.01 NTU, whichever is greater
Omgivelsestemperatur:
0 - 50 °C
-10 - 50 °C
Parameter:
Turbidity, Suspended Solids
Repeterbarhed:
TSS content: < 4 %
Turbidity: < 3 %
Responstid T90:
1 – 300 s justerbar
Specielle fordele:
Simple Inline installation
Specielle notater:
Installation note:
Distance sensor–wall
> 50 cm (Turbidity)
> 10 cm (TSS)
Trykområde:
10 bar or 100 m
Vedligeholdelse interval:
1 h/måned
Vægt:
approx. 2.7 kg