Hach pHD sc Online Process pH Sensor - pH Sensor for Clean Water

Hach pHD sc Online Process pH Sensor -  pH Sensor for Clean Water
Produktnr.: DPD1R1.99
Stykpris Kontakt os
Afsendes indenfor 2 uger

Longer service life

This field-proven technique uses three electrodes instead of the two normally used in conventional pH sensors. Process and reference electrodes measure the pH differentially with respect to a third ground electrode. The end result is unsurpassed measurement accuracy, reduced reference junction potential, and elimination of sensor ground loops. These sensors provide greater reliability, resulting in less downtime and maintenance.

2 years phased warranty

The double junction salt bridge creates a barrier to contamination which minimizes the dilution of the internal standard cell solution. The result is lower maintenance needs and a longer time period between calibrations.

Plug and play with SC controllers

The unique, replaceable salt bridge holds an extraordinary volume of buffer to extend the working life of the sensor by protecting the reference electrode from harsh process conditions. The salt bridge simply threads onto the end of the sensor if replacement is needed.

Reliability with Built-in Encapsulated Preamp

Encapsulated construction protects the sensor’s built-in preamp from moisture and humidity, ensuring reliable sensor operation. The preamp in the pHD analogue sensor produces a strong signal, enabling the sensor to be located up to 1000 m (3280 ft.) from the analyser.

Innovative Technology

The former GLI, now a Hach Company brand, invented the Differential Electrode Technique for pH measurement in 1970. The pHD takes this field-proven technology to a new level.

Specifikationer

Compliance: Hazardous location, Maritime, CE
Drift: 0.03 pH per 24 hours, non-cumulative
Driftstemperatur : -5 - 70 °C (23 - 158 °F) pHD and ORP
0 - 50 °C (32 - 122 °F) SS pHD

Before initial pH calibration, calibrate the temperature measurement when the sensor is in water or buffer which is at approximately the same temperature as the pH buffers (matches current recommendation)
Elektrode type: General Purpose
Flow: maks.
Flowhastighed: 3 m (10 ft.) per second, maximum
Følsomhed: ± 0,01 pH
Garanti: 24 måneder
Kabelforbindelse: Digital
Kabellængde: 10 m PUR (polyurethane) 4-conductor with one shield, rated to 105°C
Kalibreringsmetode: Two point automatic, one point automatic, two point manual, one point manual.
Kommunikation: Modbus
Længde: 271.3 mm
Måleområde: -2.0 to 14.0 pH
Materiale: Ground Electrode: Titanium
  PPS
Monteringsmetode: Convertible
Nøjagtighed: ± 0,02 pH
Opbevarings-betingelser: 4 - 70 °C, 0 - 95% relative humidity (non-condensing)
Repeterbarhed: ± 0.05 pH
Sensor cable: 10 m (33 ft.) polyurethane, 4-conductor cable with one shield, rated to 105°C (221°F)
Sensor gevind: 1" NPT
Temperaturføler: NTC 300 Ω thermistor for automatic temperature compensation and analyzer temperature readout
Temperaturkompensation: Automatic with NTC 300 Ω thermistor, or manually fixed at a user-entered temperature,
additional selectable temperature correction factors (ammonia, morpholine, or user-defined pH/°C linear slope) available for pure water automatic compensation 0.0 - 50 °C
Temperatur nøjagtighed: ± 0.5 °C (± 0.9 °F)
Transmissions afstand: 1000 m (3280 ft.), maximum when used with a termination box.
  100 m (328 ft.), maximum
Trykområde: Maximum 10.7 bar . 6.9 bar for Digital Sensor at 70°C, and 6.9 bar for Analog Sensor at 105°C.
Vægt: 0,316 kg
Væskeberørte materialer: PEEK or PPS, salt bridge of matching material with PVDF junction, glass process electrode, titanium ground electrode, and FKM/FPM O-ring seals (pH sensor with optional HF-resistant glass process electrode has 316 stainless steel ground electrode, and perfluoroelastomer wetted O-rings; consult factory for other available wetted O-ring materials)