EZ7300 Microbial Activity ATP Analyser

EZ7300 Microbial Activity ATP Analyser
Produktnr.: EZ7300.XXXXXXXX
Stykpris Kontakt os

Hvad er der i boksen

EZ7300 ATP Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 2 x empty 5L Reagent Container with Fittings (NaOH & HCl Solution) and 3 x Screwcap/Fittings/Reference1/Reference2

Specifikationer

Afløb: Atmospheric pressure, vented, min. Ø 32 mm
Alarm: 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Analoge udgange: Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Antal prøver pr. kanal: 1, 2, 4, or 8
Beskyttelsesklasse: Analyser cabinet: IP44 / Panel PC: IP65
Certificeringer: CE compliant / UL certified
Demineralised water: For rinsing
Detektionsgrænse: ≤ 0.05 pg/mL (0.1 pM) ATP
Digital outputs: Optional: Modbus (TCP/IP, RS485)
Dimensioner (H x B x D): 690 mm x 465 mm x 330 mm
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Flowhastighed: 100 - 300 mL/min
Garanti: 24 måneder
Hvad er der i boksen: EZ7300 ATP Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 2 x empty 5L Reagent Container with Fittings (NaOH & HCl Solution) and 3 x Screwcap/Fittings/Reference1/Reference2
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferenser: High concentrations of Hg2+, Cu2+, Zn2+, Cd2+, Fe2+. Total salt concentrations higher than 1 g/L. pH lower than 5.5 and higher than 8.
Kalibrering: Automatic, 2-point; frequency freely programmable
Kuvetter: 7 - 10 minutes incl. sample lysis
Målemetode: Determination of adenosine triphosphate (ATP) by means of chemiluminescent reaction using luciferin and luciferase, conform with standard method ASTM D4012-81
Måleområde: 0.5 - 200 pg/mL
  0.5 - 200 pg/mL
Materiale: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Model: EZ7300
Omgivelsestemperatur: 7 - 23 °C ±4 °C deviation at 5 - 95% relative humidity (non-condensing)
Parameter: ATP
Precision: Better than 4% full scale range for standard test solutions
Prøvetemperatur: 5 - 30 °C
Reagent Requirements: Keep between 4 - 8 °C during operation, shielded from light. For prolonged storage, store at -20 °C in a dark environment.
strøm: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Strømforsyning: 100 - 240 VAC, 50/60 Hz
Tryk: Maximum 3 bar for direct injection or by external overflow vessel via the grab sample pump
Validation: Automatic; frequency freely programmable
Vægt: 30 kg