EZ3505 Chloride Analyser

EZ3505 Chloride Analyser
Produktnr.: EZ3505.XXXXXXXX
Stykpris Kontakt os

Hvad er der i boksen

EZ3505 Chloride Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x ISE Electrode and Chloride Electrode, combined, and 2 x empty 5L Reagent Containers with Fittings (for Buffer and Standard Cl Solution)

Specifikationer

Afløb: Atmospheric pressure, vented, min. Ø 32 mm
Alarm: 1x malfunctioning, 4x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Analoge udgange: Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Antal prøver pr. kanal: 1, 2, 4 or 8
automatisk rengøring: Ja
Beskyttelsesklasse: Protection class: Analyser cabinet: IP44 / Panel PC: IP65
Certificeringer: CE compliant / UL certified
Demineralised water: For rinsing
Detektionsgrænse: 10 mg/L
Digital outputs: Optional: Modbus (TCP/IP, RS485)
Dimensioner (H x B x D): 690 mm x 465 mm x 330 mm
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Flowhastighed: 100 - 300 mL/min
Garanti: 24 måneder
Hvad er der i boksen: EZ3505 Chloride Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x ISE Electrode and Chloride Electrode, combined, and 2 x empty 5L Reagent Containers with Fittings (for Buffer and Standard Cl Solution)
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferenser: Bromide, sulphide, iodide, cyanide ions may interfere. Mercury must be absent. Ammonia and thiosulphate may interfere. Fats, oil, proteins, surfactants and tar.
Kalibrering: Automatic, 2-point; frequency freely programmable
Kuvetter: 8 minutes
Målemetode: Discontinuous measurement by combined ion-selective electrode with standard addition
Måleområde: 50 ‐ 1000 mg/L
  50 - 1000 mg/L Cl-

Optional:
10 - 250 mg/L Cl-
25 - 500 mg/L Cl-
Materiale: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Metodenavn: Ionselective (standard addition)
Model: EZ3505
Omgivelsestemperatur: 10 - 30 °C ±4 °C deviation at 5 - 95% relative humidity (non-condensing)
Parameter: Chloride
Precision: Better than 2% full scale range for standard test solutions
Prøve kvalitet: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Prøvetemperatur: 10 - 30 °C
Reagent Requirements: Keep between 10 - 30 °C
strøm: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Strømforsyning: 100 - 240 VAC, 50/60 Hz
Tryk: By external overflow vessel
Validation: Automatic; frequency freely programmable
Vægt: 25 kg