EZ1029sc Nitrate Colorimetric Analyser, 1 stream, 4x mA Output

EZ1029sc Nitrate Colorimetric Analyser, 1 stream, 4x mA Output
Produktnr.: EZ1029.9850140T
Stykpris Kontakt os

Trusted Equipment for Critical Operations

The EZ sc Series combines robust engineering with high-quality materials to ensure reliability 24/7. Designed for long-term performance, EZ sc Series minimises breakdowns and supports sustained operational success.

Scalable Solutions for Growing Needs

Built to evolve alongside your needs, online analysers from the EZ sc Series offer adaptable parameters and easier integration. They ensure your facility remains future proof without requiring expensive upgrades. Easily adjust parameter testing ranges and expand sample streams to accommodate innovation and growth.

Real-Time Data for Faster Decisions

The EZ sc Series offers advanced connectivity and real-time monitoring, delivering immediate access to actionable insights. Facilities utilising this technology benefit from improved reaction times, empowering more informed decision-making and quicker responses during critical situations.

Simplified Troubleshooting with Expert Support

Built-in diagnostics combined with secure remote data access make the EZ sc Series simplify issue resolution. Supported by a highly responsive team of experts, it ensures uninterrupted functionality and minimises operational downtime. By addressing and identifying issues early, EZ sc Series of online analysers helps prevent costly disruptions and repairs while maintaining system efficiency.

Clear Workflows for Predictable Outcomes

Standardised tools and guided workflows ensure consistent implementation and operation. The EZ sc Series minimises miscommunication, sets clear expectations, and reduces process inconsistencies, driving greater efficiency.

Hvad er der i boksen

EZ1029 Nitrate Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Reagent Container with Fittings (for Sulfamic Acid & Buffer Solution), 1 x empty 5L Reagent Container with Fittings (for Reductor Solution) and 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour Solution)

Specifikationer

Afløb: Atmospheric pressure, vented, min. Ø 32 mm
Analoge udgange: Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard: 4, optional: 8
Antal prøver pr. kanal: Standard: 1
Optional accessory for 2, 4, or 8 sample streams
automatisk rengøring: Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Beskyttelsesklasse: IP44
Certificeringer: CE, ETL certified to UL and CSA safety standards, UKCA
Demineralised water: Internal dilution option: Rinse water & Dilution water
Detektionsgrænse: 0.2 - 10 mg/L NO₃-N: 0.2 mg/L
Digital outputs: Profibus DP or Modbus RTU
Dimensioner (H x B x D): 688 mm x 460 mm x 340 mm
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Flowhastighed: 100 - 300 mL/min
Garanti: 24 måneder
Hvad er der i boksen: EZ1029 Nitrate Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Reagent Container with Fittings (for Sulfamic Acid & Buffer Solution), 1 x empty 5L Reagent Container with Fittings (for Reductor Solution) and 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour Solution)
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
Interferenser: Ions, e.g., antimony (III) (Sb3+), bismuth (III) (Bi3+), chloroplatinate (PtCl62–), gold (III) (Au3+), iron(III) (Fe3+), lead (II) (Pb2+), mercury (II) (Hg2+), metavanadate (VO3–) and silver (I) (Ag+) can cause precipitation with nitrate. Copper (Cu2+) ions can decompose the diazonium salt cause a low result. NCl3 can cause a red color. Strong oxidizing agents interfere. Large quantities of color and turbidity interfere. Fats, oil, proteins, surfactants and tar interfere.
Kalibrering: Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced
Kuvetter: Default: 20 min.
Continuous: 16 min.
Målemetode: NEDD colorimetric method after reduction with hydrazine
Måleområde: Internal Dilution
0.2 - 10 mg/L NO₃-N
Materiale: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Omgivelsestemperatur: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Parameter: Nitrate
Precision: Better than 2% full scale range for standard test solutions
Prøve kvalitet: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Prøvetemperatur: 10 - 30 °C
Reagent Requirements: Keep Reducting reagent and Color Reagent refrigerated: 10 - 15 °C; all other between 10 - 30 °C
Relæer: 5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150)
strøm: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Tryk: By external overflow vessel (open to atmospheric pressure)
Udgang: Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP
Validation: Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Vægt: Max. 35 kg