EZ1024 Iron Analyser Fe(II+III)

EZ1024 Iron Analyser Fe(II+III)
Produktnr.: EZ1024.XXXXXXXX
Stykpris Kontakt os

Hvad er der i boksen

EZ1024 Iron Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 2 x empty 5L Reagent Container with Fittings (for Buffer & Reductor Solution) and 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour Solution)

Specifikationer

Afløb: Atmospheric pressure, vented, min. Ø 32 mm
Alarm: 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Analoge udgange: Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Antal prøver pr. kanal: 1, 2, 4, or 8
automatisk rengøring: Ja
Beskyttelsesklasse: Protection class: Analyser cabinet: IP44 / Panel PC: IP65
Certificeringer: CE compliant / ETL certified
Demineralised water: For rinsing / dilution
Detektionsgrænse: ≤ 2 µg/L
Digital outputs: Optional: Modbus (TCP/IP, RS485)
Dimensioner (H x B x D): 690 mm x 465 mm x 330 mm
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Flowhastighed: 100 - 300 mL/min
Garanti: 24 måneder
Hvad er der i boksen: EZ1024 Iron Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 2 x empty 5L Reagent Container with Fittings (for Buffer & Reductor Solution) and 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour Solution)
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferenser: Metal ions like Lead > 10 mg/L, Zinc > 2 mg/L, Nickel > 2 mg/L, Iron > 5 mg/L, Copper > 5 mg/L. Strong oxidising agents, Cyanide, Nitrite, Phosphate (polyphosphate more than orthophosphate), Chromium, Zinc in concentrations exceeding 10 times that of Iron. Bismuth, Cadmium, Mercury, Molybdate, and Silver precipitate Phenanthroline. Polyphosphate must be absent. Large amounts of colour and turbidity interfere. Fats, pil, proteins,surfactants and tar.
Kalibrering: Automatic, 2-point; frequency freely programmable
Kuvetter: 10 min Fe (II), Fe total dissolved (dilution + 5 min.)
15 min all combined parameters
Målemetode: Colorimetric measurement using TPTZ colour solution, conform with APHA 3500-Fe (B)
Måleområde: 0.01 - 1 mg/L Fe(II)
  0.01 - 1 mg/L Fe(II)

Optional:
0.005 - 0.25 mg/L
0.005 - 0.5 mg/L
0.08 - 4 mg/L (with internal dilution)
0.16 - 8 mg/L (with internal dilution)
2 - 100 mg/L (with internal dilution)
Materiale: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Model: EZ1024
Omgivelsestemperatur: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Parameter: Iron Fe(II+III), total dissolved
Precision: Better than 2% full scale range for standard test solutions
Prøve kvalitet: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Prøvetemperatur: 5 - 30 °C
Reagent Requirements: Keep between 10 - 30 °C
strøm: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Strømforsyning: 100 - 240 VAC, 50/60 Hz
Tryk: By external overflow vessel
Validation: Automatic; frequency freely programmable
Vægt: 25 kg