EZ1017 Calcium Hardness Analyser

EZ1017 Calcium Hardness Analyser
Produktnr.: EZ1017.XXXXXXXX
Stykpris Kontakt os

Hvad er der i boksen

EZ1017 Calcium Hardness Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 3 x empty 2.5L Reagent Containers with Fittings (for Colour, Acid, and EDTA Solution) and 1 x empty 5L Reagent Container with Fittings (for Buffer)

Specifikationer

Afløb: Atmospheric pressure, vented, min. Ø 32 mm
Alarm: 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Analoge udgange: Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Antal prøver pr. kanal: 1, 2, 4, or 8
automatisk rengøring: Ja
Beskyttelsesklasse: Analyser cabinet: IP44 / Panel PC: IP65
Certificeringer: CE compliant / ETL certified
Demineralised water: For rinsing / dilution
Detektionsgrænse: ≤ 2.5 µg/L CaCO3
Digital outputs: Optional: Modbus (TCP/IP, RS485)
Dimensioner (H x B x D): 690 mm x 465 mm x 330 mm
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Flowhastighed: 100 - 300 mL/min
Garanti: 24 måneder
Hvad er der i boksen: EZ1017 Calcium Hardness Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 3 x empty 2.5L Reagent Containers with Fittings (for Colour, Acid, and EDTA Solution) and 1 x empty 5L Reagent Container with Fittings (for Buffer)
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferenser: Dissolved Copper Cu(II) > 2 mg/L, Iron Fe(II) > 20 mg/L, Manganese > 10 mg/L, Zinc > 5 mg/L, Lead > 5 mg/L, Aluminium > 5 mg/L and Tin Sn(IV) interfere. Orthophosphate precipitates Calcium at the pH of the test. Strontium and Barium give a positive interference and alkalinity in excess of 300 mg/L may cause an indistinct end point in hard waters. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Kalibrering: Automatic, 2-point; frequency freely programmable
Kuvetter: 10 min (dilution + 5 min.)
Målemetode: Colorimetric measurement at 610 nm using hydroxynaphthol blue/EDTA
Måleområde: 0.025 - 1 mg/L CaCO3

Optional:
0.005 - 0.25 mg/L
0.005 - 0.5 mg/L
0.2 - 4 mg/L (with internal dilution)
0.4 - 8 mg/L (with internal dilution)
0.25 - 10 mg/L (with internal dilution)
0.625 - 25 mg/L (with internal dilution)
1.25 - 50 mg/L (with internal dilution)
1.875 - 75 mg/L (with internal dilution)
2.5 - 100 mg/L (with internal dilution)
  0.025 - 1 mg/L CaCO₃
Materiale: Hinged part: Thermoform ABS, door: PMMA
Wall section: galvanised steel, powder coated
Metodenavn: Colorimetric
Model: EZ1017
Omgivelsestemperatur: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Parameter: Calcium Hardness
Precision: Better than 2% full scale range for standard test solutions
Prøve kvalitet: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Prøvetemperatur: 10 - 30 °C
Reagent Requirements: Keep between 10 - 30 °C
strøm: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Tryk: By external overflow vessel
Validation: Automatic; frequency freely programmable
Vægt: 25 kg