EZ1009 Chromium Cr(VI) Analyser

EZ1009 Chromium Cr(VI) Analyser
Produktnr.: EZ1009.XXXXXXXX
Stykpris Kontakt os

Hvad er der i boksen

EZ1009 Chromium Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour) and 1 x empty 5L Reagent Container with Fittings (for Buffer Solution)

Specifikationer

Afløb: Atmospheric pressure, vented, min. Ø 32 mm
Alarm: 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Analoge udgange: Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Antal prøver pr. kanal: 1, 2, 4, or 8
automatisk rengøring: Ja
Beskyttelsesklasse: Analyser cabinet: IP44 / Panel PC: IP65
Certificeringer: CE compliant / ETL certified
Demineralised water: For rinsing / dilution
Detektionsgrænse: ≤ 1 µg/L
Digital outputs: Optional: Modbus (TCP/IP, RS485)
Dimensioner (H x B x D): 690 mm x 465 mm x 330 mm
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Flowhastighed: 100 - 300 mL/min
Garanti: 24 måneder
Hvad er der i boksen: EZ1009 Chromium Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour) and 1 x empty 5L Reagent Container with Fittings (for Buffer Solution)
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferenser: Iron (III), Mercury > 200 mg/L, Molybdenum > 200 mg/L, Vanadium (V) > 5 mg/L.
Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Kalibrering: Automatic, 2-point; frequency freely programmable
Kuvetter: 10 min (dilution + 5 min)
Målemetode: Colorimetric measurement at 546 nm using diphenylcarbazide method, conform with standard method APHA 3500-Cr (B)
Måleområde: 5 - 500 µg/L Cr(VI)
  5 - 500 µg/L Cr(VI)

Optional:
1 - 50 µg/L Cr(VI)
2 - 125 µg/L Cr(VI)
2.5 - 250 µg/L Cr(VI)
0.08 - 2 mg/L Cr(VI) (with internal dilution)
0.16 - 4 mg/L Cr(VI) (with internal dilution)
0.5 - 50 mg/L Cr(VI) (with internal dilution)
Materiale: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Model: EZ1009
Omgivelsestemperatur: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Parameter: Chromium Cr(VI), dissolved
Precision: Better than 2% full scale range for standard test solutions
Prøve kvalitet: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Prøvetemperatur: 10 - 30 °C
Reagent Requirements: Keep between 10 - 30 °C
strøm: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Strømforsyning: 100 - 240 VAC, 50/60 Hz
Tryk: By external overflow vessel
Validation: Automatic; frequency freely programmable
Vægt: 25 kg