CLF10 sc Free chlorine analyser, pH combination sensor, metric

CLF10 sc Free chlorine analyser, pH combination sensor, metric
Produktnr.: LXV45A.98.22022
Stykpris Kontakt os

Disinfection under control

Hach's self diagnostics alerts you when the process has changed or when the instument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting sample flow sensor for notification of insufficient sample flow. All warnings are easy to configure.

Minimal operation costs

The amperometric sensors monitor chlorine concentration continuously without reagents. There is no need to replace reagents nor to manage disposal. This saves time and keeps operation costs at a low level.

Plug and play

The sensors are designed for all Hach digital SC controllers so you only need one controller for all measurements. They are easy to operate, no matter if measuring turbidity or chlorine. Hach SC controllers have no complicated wiring or setup procedures. Just plug in any Hach digital sensor and it’s ready to use without software configuration.

Real-time process control

Continuous readings indicate when treatment conditions have changed allowing CLT10 sc and CLF10 sc a real-time control of disinfection processes.

EPA compliant according to Method 334.0

In accordance with the US EPA Method 334.0, the sensors can be used for reporting chlorine residual measurements.

Hvad er der i boksen

CL10sc Panel, 1 m Digital Extension Cable, pH Combination Sensor, Panel Manual, Chlorine Sensor Manual, pH Combination Sensor Manual

Specifikationer

Bredde: 495.3 mm
Certificeringer: CE/ETL, EMC
Detektionsgrænse: 30 ppb (0.03 ppm)
Dimensioner: mm x 25 mm (7.68 in x 0.98 in)
  Sensor Only: 195
Flowhastighed: 30 - 50 L/h, Optimal is 40 L/hour
flowhastighed: Metric
Forbindelse afløb: 1/2 in ID
Forbindelse prøve: 1/4 in OD
Garanti: 24 måneder
Hvad er der i boksen: CL10sc Panel, 1 m Digital Extension Cable, pH Combination Sensor, Panel Manual, Chlorine Sensor Manual, pH Combination Sensor Manual
Indstillinger: Combination pH Sensor
Interferenser: Free chlorine: monochloramine, chlorine dioxide, ozone, and chalk deposits.
Total chlorine: chlorine dioxide, ozone and chalk deposits
Kabelforbindelse: 5 pin, M12 connector
Kabellængde: 1 m (between gateway and sc controller)
Kalibreringsmetode: 1-point or 2-point (zero and slope) calibration
Kompatibel med: SC200, SC1000, SC4500. All controllers sold separately
Kontrolenhed: Panel only
Længde: Sensor: 195 mm
Målemetode: Reagentless, electrochemical, three-electrode amperometric system
Måleområde: 0 - 20 ppm Cl₂
Materiale: Panel: Corrosion-resistant, fully-submersible (stainless steel, PVC, silicon rubber and polycarbonate)
Monteringsmetode: Flat, vertical surface
Nøjagtighed: Free Chlorine: ± 10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
  Free Chlorine: ± 3 % of the reference test** (DPD) at constant pH less than 7.2 (±0.2 pH unit)
  Total Chlorine: ± 10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
  Total Chlorine: ± 20 % of the reference test** (DPD) at stable pH greater than 8.5
Omgivelsestemperatur: 0 - 45 °C
Opbevarings-betingelser: -20 °C - 60 °C dry
Parameter: Free Chlorine
pH måleområde: 4 - 9
pH Monitoring Required?: With combination pH sensor
Prøvetemperatur: 5 - 45 °C
Repeterbarhed: 30 ppb eller 3%, alt efter hvilken er størst
Responstid: Free Chlorine: 140 s or less for 90% change (T90)
at a stable temperature and pH
  Total Chlorine: 100 s or less for 90% change (T90)
at a stable temperature and pH
Strømkrav (volt): Ingen
Temperaturkompensation: Internal temperature compensation in the sensor
  Interne temperatuurcompensatie in de sensor
Trykområde: 0.5 bar, no pressure impulses and/or vibrations
Vægt: Approximately 5.5 kg
Panel and empty panel-mounted components only