TSS W sc Inline suspended solids probe, stainless steel, with wiper

TSS W sc Inline suspended solids probe, stainless steel, with wiper
Produktnr.: LXV324.99.30001
Stykpris Kontakt os
Afsendes indenfor 1 uge

TSS sc probes have been specially developed for industrial applications

Measures both turbidity and suspended solids

8 measurement signals cover the total range and deliver measured values in conformity with the relevant standards

Excellent stability thanks to comprehensive compensation for interference factors

TSS sc has a unique compensation system to overcome the effects of air bubbles

Hvad er der i boksen

Turbidity & Suspended Solids sensor, user manual

Specifikationer

Applikation: Standard
automatisk visker: Ja
Diameter: 40 mm
Flow: Max. 3 m/s (the presence of air bubbles affects the measurement)
Garanti: 24 måneder
Hvad er der i boksen: Turbidity & Suspended Solids sensor, user manual
installationsstil: Ball Valve Insertion
Kabellængde: 10 m (optional extension cables available)
Kalibrering: Turbidity (TRB): Factory calibrated
Solids (TS): To be calibrated by customer on site
Zero point: Permanently calibrated in the factory
Kalibreringsmetode: Turbidity: Formazin or Stablcal Standard (at 800 NTU). Requires a calibration kit.
Suspended Solids: Sample specific, based on gravimetric analysis with a correction factor procedure.
Kompatibel med: SC200, SC1000, SC4500. All controllers sold separately
Længde: 332 mm
Målemetode: Combined multiple beam alternating light method with infrared diode system and beam focusing
Turbidity (TRB): 2-channel 90º scattered light measurement in accordance with DIN EN ISO 7027, wavelength = 860 nm
Solids (TS): 90º and 120º scattered light measurement, wavelength = 860 nm
Måleområde: Turbidity (TRB): 0.001 - 9999 NTU
Solids (TSS): 0.001 - 500 g/L
Materiale: Optics Carrier and Sleeve: stainless steel 1.4460 / stainless steel 1.4571; Wiper Arm: PA (GF); Wiper Rubber: TPV; Wiper Shaft: stainless steel 1.4571
Max Temperatur: 50 °C
Measuring range TSS: 0,001 - 500 g/L
Measuring range turbidity: 0,001 - 9999 FNU
Model: TSS W sc
Monteringskonfigurationer: Insertion
Nøjagtighed: Turbidity up to 1000 FNU/NTU: < 5 % of measurement value or ±0.01 NTU, whichever is greater
Omgivelsestemperatur: 0 - 50 °C
  0 - 60 °C (briefly 80 °C)
Parameter: Turbidity, Suspended Solids
Repeterbarhed: TSS content: < 4 %
Turbidity: < 3 %
Responstid T90: 1 – 300 s justerbar
Specielle fordele: With Wiper for Simple Inline Installation
Specielle notater: Installation note:
Distance sensorwall
> 50 cm (Turbidity)
> 10 cm (TSS)
Trykområde: < 6 bar or < 60 m
Vedligeholdelse interval: 1 h/måned
Vægt: Approx. 1.6 kg